Technical Data
- Materials :
- PVC-U to DIN 4925 and DIN 8061
- Lengths :
- Normally supplied in 2.85m and 5.8m overall lengths to fit inside standard containers for economical land and sea transport. Other lengths available on request.
- Slot Sizes :
- Available in a range of slot widths 0.2, 0.3, 0.5, 0.75, 1.0, 1.5, 2.0 and 3.0mm.
- Thread Style :
- Mechanical jointing by threaded connection to DIN 4925. Whitworth threads on small sizes and Trapezoidal threads on larger sizes from 100/4" and up.
- Joints :
- Each length is supplied with a Male/Female socketed joint as standard. Flush joints can be supplied on thickwalled pipe.
- Marking :
- Standard marking is applied to all casing and screen and includes OD and WT.
Table I: Mechanical & Thermal Properties
Unplasticized polyvinylchloride (PVC-U), without plasticizers and fillers.
| Properties |
Units |
Testing Method |
Specification |
Specified Value |
Long Term Creep Pressure For 1000 hours |
N/mm2 |
DIN 53795 |
DIN 8061 |
10 |
Impact Resistance (Confidence Limit) at 23 ± 2 C |
% |
DIN 53453 |
DIN 8061 |
Min 90 |
| Water Absorption |
mg/cm2 |
DIN 8061 |
DIN 8061 |
Max 4 |
| Heat Reversion |
% |
DIN 8061 |
DIN 8061 |
Max 5 |
| Density |
gm/cc |
DIN 53479 |
DIN 8061 |
1.4-1.45 |
Mean Coefficient of linear thermal expansion in the temperature range 0 to 70 °C |
k-1 |
DIN 53752 |
DIN 8061 |
0.8 x 10-4 |
| Thermal Conductivity |
w/km |
DIN 52612 Part 1 |
DIN 8061 |
0.15 |
| Surface Resistance |
Ω |
DIN 53482/ VDE 0303 Part 3 |
DIN 8061 |
1012 |
| Vicat Softening Temp |
°C |
DIN 53460 B |
DIN 4925 |
80 °C |
| Yield Point |
N/mm2 |
DIN 53455 |
DIN 4925 |
45 to 55 |
- * PVC-U is generally resistant to:
- All type of ground water, sea water and brines, diluted Acids, diluted Alkalines
The use of non-corroding PVC-U for well casing and screen offers significant advantages over steel and other materials. The excellent properties of PVC-U guarantee the maximum possible operating life of the well in many applications.
|
Table II: Range of PVC-U Well Casings & Screens to DIN 4925
Nom Diam (mm/inch) OD |
Outside Diam (mm) d |
Wall Thickness (mm) s |
Outside Diam of Socket (mm) d5 |
Inside Diam of Pipe (mm) d1 |
| STANDARD WALL |
|
|
|
|
| 35/1.25" |
42 |
3.5 |
46 |
35 |
| 40/1.5" |
48 |
3.5 |
52 |
41 |
| 50/2" |
60 |
4 |
65 |
52 |
| 80/3" |
88 |
4 |
95 |
80 |
| 100/4" |
113 |
5 |
120 |
103 |
| 125/5" |
140 |
6.5 |
148 |
127 |
| 150/6" |
165 |
7.5 |
176 |
150 |
| 200/8" |
225 |
10.0 |
240 |
205 |
| 250/10" |
280 |
12.5 |
300 |
255 |
| 300/12" |
330 |
14.5 |
350 |
301 |
| 350/14" |
400 |
17.5 |
415 |
365 |
| 400/16" |
450 |
19.5 |
485 |
411 |
| THICK WALLED |
|
|
|
|
| 100/4" |
113 |
8.2 |
125 |
96.6 |
| 125/5" |
140 |
8.0 |
150 |
124 |
| 150/6" |
165 |
9.5 |
180 |
146 |
| 200/8" |
225 |
13.0 |
245 |
199 |
| 250/10" |
280 |
16.0 |
300 |
248 |
| 300/12" |
330 |
19.0 |
355 |
292 |
| 350/14" |
400 |
21.0 |
430 |
358 |
| Note: 1. Other sizes conforming to BS and ASTM standards can be supplied on request.
|
Table III: Range of PVC-U Screens with Ribbed Surface
Nom Diam (mm/inch) |
Outside Diam (mm) d |
Wall Thickness (mm) s |
Outside Diam of Ribs (mm) d2 |
Outside Diam of Socket (mm) d5 |
| 40/1.5" |
48 |
3.5 |
52 |
56 |
| 50/2" |
60 |
4 |
64 |
68 |
| 80/3" |
88 |
4 |
92 |
98 |
| 100/4" |
113 |
5 |
117 |
125 |
| 125/5" |
140 |
6.5 |
145 |
154 |
| 150/6" |
165 |
7.5 |
170 |
180 |
| 200/8" |
225 |
10.5 |
230 |
245 |
- More Informations:
-
- Screen & Casing Assembly
- Specifications for Sizes
- Dimensions and Arrangements of Slots
- Screw Threads
- Usage and Installation
- HDPE Casing & Screens